| Specification | Value | Condition |
| Current Rating (Standard Signal Contact) | 1.5A max | One contact loaded, 25C ambient |
| Current Rating (Standard Signal Contact) | 1.0A max | One contact loaded, 85C ambient |
| Current Rating (Standard Signal Contact) | 1.0A max | All contacts loaded, 25C ambient |
| Current Rating (Standard Signal Contact) | 0.7A max | All contacts loaded, 85C ambient |
| Current Rating (T-Contact) | 8.5A max | One contact loaded, 25C ambient |
| Current Rating (T-Contact) | 6.5A max | One contact loaded, 85C ambient |
| Current Rating (T-Contact) | 3.5A max | All contacts loaded, 25C ambient |
| Current Rating (T-Contact) | 2.6A max | All contacts loaded, 85C ambient |
| Current Rating (Flex Circuit Assembly) | 1.0A max | Per individual track, 25C ambient |
| Working Voltage | 300V DC or AC peak | Pre-Cabled Contacts & Cable Assemblies |
| Working Voltage | 800V DC or AC peak | Standard Signal Contacts |
| Voltage Proof | 1,200V DC or AC peak | (at 1,013mbar, sea level) |
| Contact Resistance | 20m max | Initial |
| Contact Resistance | 25m max | After Conditioning |
| Insulation Resistance | 1,000M min | Initial |
| Insulation Resistance | 100M min | After Conditioning |
| Creepage Path | 0.35mm min | Contact-to-contact |
| Air Gap | 0.35mm min | Contact-to-contact |
| Environmental Classification | 55/125/56 | Days at 95% RH |
| Operating Temperature Range | -55C to +125C | |
| Low Air Pressure Severity | 300 mbar (9,144m/30,000ft) | (only one contact loaded) |
| Salt Spray (SRS) | Severity 2 | BS2011 Part 2.1Kb (5% Solution, 6.5/7.2pH @ 40C, 93% RH for 66 hours) |
| Salt Spray (J-Tek & Mix-Tek) | Condition A | EIA364 Test Procedure 26 (5% Solution, 6.5/7.2pH @ 35C, 95% RH for 96 hours) |
| Vibration Severity (Standard Signal) | 10Hz to 2,000Hz, 0.75mm, 98m/s (10G) | 6 hours duration |
| Vibration Severity (Standard Signal) | 10Hz to 81.73Hz (1.5mm pp), 57.55Hz to 2,000Hz (196.2m/s) | 2 hours duration (20G test) |
| Shock Severity (Standard Signal) | 981m/s (100G) | 18 shocks total |
| Bump Severity (Standard Signal) | 390m/s (40G) | 4,000+10 bumps |
| Vibration Severity (T-Contact) | 10Hz to 13.6Hz (35mm pp), 13.6Hz to 41.6Hz (1.5mm pp), 41.6Hz to 2,000Hz (392.4m/s) | 6 hours duration |
| Shock Severity (T-Contact) | 981m/s (100G) | |
| Clip Retention in Body | 18N min | |
| Contact Retention in Housing | 10N min | |
| Contact Replacement in Housing (Male Crimp Jackscrew) | 2 operations at 10N | |
| Durability (Standard Signal Contact) | 500 operations | |
| Durability (T-Contact) | 1,000 operations | |
| Contact Holding Force (Standard Signal Contact) | 0.2N min | |
| Insertion Force (per contact) | 2.0N max | M80 Standard Signal Contact |
| Insertion Force (per contact) | 1.0N max | M83 Signal Contact |
| Insertion Force (per contact) | 4.0N max | T-Contact |
| Withdrawal Force (per contact) | 0.2N min | M80 Standard Signal Contact |
| Withdrawal Force (per contact) | 0.2N min | M83 Signal Contact |
| Withdrawal Force (per contact) | 0.5N min | T-Contact |
| Cable Contact Replacement in Housing | Up to 2 times max | |
| Contact Wipe (T-Contact) | 2.00mm min | |