86--13264592152

HOOYA USB-310M-B-SU

Manufacturer: HOOYA
Model Number: USB-310M-B-SU
Minimum Order Quantity: 550
Packaging Details: SMD
Delivery Time: 5-6 weeks
Stock: 5500
Description: USB-C (USB TYPE-C) Receptacle Connector 16 Position Surface Mount, Right Angle
Inquiry Now
Get A Quote
Specifications
Number Of Ports:
1
Number Of Contacts:
16P
Mounting Type:
Surface Mount, Right Angle
Current Rating:
3A
Voltage Rating:
30V
Operating Temperature:
-30℃~+80℃
Connector Type:
Type-C
Connect-Disconnect Life:
10,000 Cycles
Gender:
Female
Product Description

Product Overview

This document outlines the electrical and environmental performance specifications for the HS45E product from HAOYU (HONG KONG) LIMITED, adhering to various EIA and MIL-STD test methods.

Brand HAOYU (HONG KONG) LIMITED
Part Number SPEC-USB-001
Item Description Test Methods Test Specification
7.1 Insulation Resistance EIA 364-21C 100M minimum (unmated) between adjacent contacts and contacts and shell/ground. Apply 100Volts DC.
7.2 Low Level Contact Resistance EIA 364-23b 40m (Max) initial for VBUS and GND contacts; 10m (Max) initial for all other contacts. Delta 10m (Max) after test. 20mV Max. open circuit at 100mA.
7.3 Dielectric Withstanding Voltage EIA 364-20 There shall be no breakdown when subjected to 100VAC (RMS) for 1 minute between adjacent terminals.
7.4 Contact Current Rating EIA364-70 5.0A applied collectively to VBUS pins, 1.25A to VCONN pin, and 0.25A to other contacts. Temperature rise shall not exceed 30C.
3.x Durability EIA 364-09 10000 cycles. Must meet contact resistance (delta 10m Max), insertion force (5N-20N), extraction force (8N-20N), and visual inspection criteria.
3.x Cable Flexing EIA 364-41 100 cycles in 2 planes at 120 degrees. No discontinuity over 1 microsecond or physical damage.
3.x Cable Pull-Out EIA-364-38 40N steady state axial load for 1 minute. No discontinuity or physical damage.
3.x 4-axes continuity test EIA364-18 8N tensile force for 10 seconds in 0, 90, 180, 270 directions. No discontinuity > 1s or physical damage.
8.1 Temperature Life EIA 364-17 105C without applied voltage for 120 hours. Also 72 hours for preconditioning. Visual inspection required.
8.2 Thermal Shock EIA 364-32 10 Cycles -55C and +85C. Mated connectors. No evidence of physical damage.
8.3 Salt Spray MIL-STD-202F, Method 101D, Condition B 48 hours at 35C with 5% Salt-solution. Shall meet visual requirements and show no physical damage.
8.4 Humidity EIA 364-31 90% RH @ 25C for 24 hours, then 95% RH @ 65C for 24 hours. Shall meet visual requirements and additional tests as specified.