| RATING () |
| | 5 V 3 A |
| PRACTICAL TEMPERATURE RANGE () |
| | -30 C ~ 85C |
| STANDARD ATMOSPHERIC CONDITIONS ( ) |
| (1) BETWEEN BODY AND CONDUCTOR | 5 C TO 35 |
| (2) BETWEEN CONDUCTORS NOT TO BE CONTACT | 45% TO 85% |
| (3) PRESSURE | 86Kpa TO 106Kpa |
| MECHANICAL () |
| 1 CONNECTION FORCE () | MEASUREMENT SHALL BE MADE AFTER CONNECTING AND DISCONNECTING USING STANDARD PLUG GAUGE 3 TIMES. | 0.5~2.0Kgf |
| DISCONNECT FORCE () | MEASUREMENT SHALL BE MADE AFTER CONNECTING AND DISCONNECTING USING STANDARD PLUG GAUGE 3 TIMES. | 0.8~2.0Kgf |
| 2 TERMINAL STRENGTH () | A STATIC LOAD OF 0.1N/m(1kgf/cm)SHALL BE APPLIED TO THE TIP OF THE TERMINAL FOR 1 MIN IN ANY DIRECTION | THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS CRACKS, LOOSENESS OR PLAY ELECTRICAL ,AND MECHANICAL CHARACTERISTICS SHALL BE SATISFIED |
| ELECTRICAL () |
| 3.1 CONTACT RESISTANCE () | MEASURED AT SMALL CURRENT 100mA OR LESS 1000Hz | 40m MAX |
| 3.2 INSULATION RESISTANCE () | APPLYA VOLTAGE OF 100V DC FOR 1 MIN TO FOLLOWING PORTIONS AFTER WHICH MEASUREMENT SHALL BE MADE: (1) BETWEEN BODY AND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACT (3) BETWEEN CONDUCTORS NOT TO BE WHEN PLUG IS INSERTED | 100M MIN |
| 3.3 DIELECTRIC STRENGTH () | AC 100V ims(50~60Hz)FOR 1 MIN TRIP CURRENT:0.5mA (1) BETWEEN BODY AND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACL (3) BETWEEN CONDUCTORS NOT TO BE WHEN PLUG IS INSERTED | WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC |
| DURABILITY () |
| 4.1 SOLDERA-BILITY TEST () | THE TOP OF THE TERMINALS SHALL BE DIPPED 1mm IN THE SOLDER BATH OF 2505FOR 50.5 SECONDS | (1) SOLDER WETTING TIME SHALL BE 3 SEC OR LESS (2) THE AREA OF SOLDERING SHOULD BE OVER 75% |
| 4.2 RESISTANCE TO SOLDERING HEAT TEST () - REFLOW | REFLOW SOLDERING CONDITIONS: PREHEAT:TEMPERATURE ON THE COPPER FOIL SURFACE SHOULD REACH 180.120S AFTER THE P.C.B ENTERED INTO THE SOLDERING EQUIPMENT. TALLEST TEMPERATURE:TEMPERATURE ON THE COPPER FOIL SURFACE SHOULD REACH THE PEAK TEMPERATURE OF 2605WITH IN 20 SECONDS. | WITHOUT DEFOR MATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED |
| 4.2 RESISTANCE TO SOLDERING HEAT TEST () - IRON | SOLDERING IRON METHOD: BIT TEMPERATURE 3305 APPLICATION TIME OF SOLDERING IRON 30.5 SEC HOWEVER EXCESSIVE PRESSURE SHALL NOT BE APPLIED TO THE TERMINAL | WITHOUT DEFORMATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED |
| 4.3 HUMIDITY TEST () | THE JACK SHALL BE STORED ATA TEMPERATURE OF 402AND A HUMIDITY OF 90%TO 96% FOR 96 Hr,THEN THE JACK SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 Hr FOR OTHER PROCEDURES | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED |
| 4.4 HEAT TEST () | THE JACK SHALL BE STORED ATA TEMPERATURE OF 702FOR 96 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY MBASURBM | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED |
| 4.5 COLD TEST () | THE JACK SHALL BE STORED ATA TEMPERATURE OF -253FOR 96 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED |
| 4.6 LIFE TEST () | (1) WITHOUT LOAD: CONNECTION AND DISCONNECTION SHALL BE MADE WITH THE MATING PLUGS AND JACKS FOR 5000 CYCLES AT A SPEED OF 10 TO 25 CYCLES/MIN (2) LOAD: AT RATING CONDITION NON-INDUCTIVE LOAD CONNECTION AND DISCONNECTION SHALL BE MADE 5000 CYCLES AT A SPEED 10 TO 20 CYCLES / MIN | (1) CONTACT RESISTANCE SHALL BE 0.1 (2) DISCONNECTION FORCE SHALL BE 0.8 TO 2.0N (3) MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED |
| 4.7 TEMPARATURE CYCLING TEST () | THE JACK SHALL BE SUB JECTED TO 5 CYCLES OF THE FOLLOWING CONDITIONS SHOWED IN THE FIGURE,AND THEN SHALL RETURNED ALLOWED TO REMAIN IN ROOM AMBIENT CONDITION FOR 30 MINUTES | THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART. INSERTION EXTRACTION FORCE:3 TO 20N CONTACT RESISTANCE:MAX.30M INSULATION RESISTANCE: MIN.100 M DIELECTRIC WITHSTANDING VOLTAGE: 100VAC/MIN(BETWEEN TERMINALS) |
| 4.8 COLD&HEAT SHOCK TEST () | THE JACK SHALL BE SUBJECTED TO 5 CYCLES OF THE FOLLOWING CONDITIONSSHOWED IN THE FIGURE,AND THEN SHALL RETURNED AND ALLOWED TO REMAIN IN ROOM AMBIENT CONDITION FOR 30MINUTES | THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART. INSERTION EXTRACTION FORCE:3 TO 25N CONTACT RESISTANCE:MAX.30M INSULATION RESISTANCE: MIN.100 M DIELECTRIC WITHSTANDING VOLTAGE: 500VAC/MIN(BETWEEN TERMINALS) |