| 1.1 Application Condition | | |
| Operating Environment | Temperature: -40C to +90C, Relative Humidity: 25%~85%, Without loss of function. | |
| Storage Environment | Temperature: -55C to +100C, Relative Humidity: 95% or Less, Without loss of function. | |
| 1.1.3 Ratings | | |
| Voltage Rating | 60VAC | |
| Nominal characteristic impedance | 50 | |
| Frequency | DC0.1~6GHz | |
| VSWR | Plug: 1.3Max. (DC0.1~3GHz), 1.5Max. (3~6GHz) Receptacle: 1.3Max. (DC0.1~3GHz), 1.4Max. (3~6GHz) | |
| 1.2 Health, Safety and Environment | All hazardous substances contained in this product should comply with the regulations specified by SGS. | |
| 1.3 Test Conditions | | |
| Temperature | 15~35 | |
| Humidity | 45% ~ 75% | |
| 1.4 Test Requirements and Methods | | |
| 1.4.1 Product Appearance | All components shall be properly assembled and free of burrs, warps, scratches, broken chips, and other abnormalities. | Visual inspection complies with applicable specification and document. Method: EIA 364-18B. |
| 1.4.2 Low Level Contact Resistance | Initial: 20m Max. Final: 70m Max. | |
| 1.4.3 Insulation Resistance | Initial: 500 M Min. Final: 100 M Min. | Apply 100V DC for 1 minute between adjacent contacts. Method: EIA-364-21D. |
| 1.4.4 Dielectric Withstanding Voltage | Current leakage: 0.50 mA Max. No evidence of breakdown or flash burn. | Apply 300V AC for 1 minute between plug and receptacle. Method: EIA-364-20D, Test Method B. |
| 1.4.5 VSWR | Frequency: 100MHz~6GHz | Measured by network analyzer. |
| 1.4.6 Un-mating force | Initial: 5N Min. After 30 cycles: 3N Min. | Push-on/pull-off speed: 253mm/minute. Method: EIA 364-09C. |
| 1.4.7 Crimp strength | 5N MIN | Pull the cable at a speed of 253mm/minute by tensile strength machine. |
| 1.4.8 Durability | Center conductor contact resistance: Initial 20m Max., After test 40m Max. Ground contact resistance: Initial 20m Max., After test 40m Max. Appearance: No abnormality. | Mate and un-mate 30 cycles at a speed of 253mm/minute. Method: EIA 364-09C. |
| 1.4.9 Cable retention force | Center conductor contact resistance: Initial 20m Max., After test 40m Max. Ground contact resistance: Initial 20m Max., After test 40m Max. Electrical discontinuity: No discontinuity greater than 1 micro-sec. | Apply force on the cable. Run 100mA DC during testing. |
| 1.4.10 Vibration | Appearance: No abnormality. Electrical discontinuity: No discontinuity greater than 1 micro-sec. Center conductor contact resistance: Initial 20m Max., After test 40m Max. Ground contact resistance: Initial 20m Max., After test 40m Max. | Frequency: 10Hz-100Hz-10Hz/approx 20 minutes. Half amplitude, peak acceleration: 1.5mm or 59m/s(6G). Directions: 3 mutually perpendicular directions, 3 cycles each. Run 100mA DC during testing. Method: EIA 364-28E. |
| 1.4.11 Physical shock | Appearance: No abnormality. Electrical discontinuity: No discontinuity greater than 1 micro-sec. Center conductor contact resistance: Initial 20m Max., After test 40m Max. Ground contact resistance: Initial 20m Max., After test 40m Max. | Peak acceleration: 735m/s(75G). Duration: 11msec. Wave Form: half sinusoidal. Directions: 6 mutually perpendicular, 3 cycles each. Run 100mA DC during testing. Method: EIA 364-27B. |
| 1.4.12 Humidity | Appearance: No abnormality. Center conductor contact resistance: Initial 20m Max., After test 40m Max. Ground contact resistance: Initial 20m Max., After test 40m Max. Insulation resistance: Initial 500M Min., After test 100M Min. Dielectric Withstanding Voltage: No creeping discharge, flashover, nor insulator breakdown. | Temperature: 402, Humidity: 90~95%RH, Duration: 96 hours. Method: EIA 364-31C, Method II, Condition A. |
| 1.4.13 Thermal shock | Appearance: No abnormality. Center conductor contact resistance: Initial 20m Max., After test 40m Max. Ground contact resistance: Initial 20m Max., After test 40m Max. Insulation resistance: Initial 500M Min., After test 100M Min. Dielectric Withstanding Voltage: No creeping discharge, flashover, nor insulator breakdown. | Cycles: 5 cycles of -55 (30 min) 85 (30 min). Transition time: 5 min Max. Method: EIA 364-32E. |
| 1.4.14 Temperature Life | Appearance: No abnormality. Center conductor contact resistance: Initial 20m Max., After test 40m Max. Ground contact resistance: Initial 20m Max., After test 40m Max. | Temperature: 902, Duration: 96 hours. Method: EIA 364-17B. |
| 1.4.15 H2S Gas | Appearance: No abnormality, performance is good. Center conductor contact resistance: Initial 20m Max., After test 40m Max. Ground contact resistance: Initial 20m Max., After test 40m Max. | Temperature: 402, Relative Humidity: 805%RH, Gas: H2S 31ppm, Duration: 96 hours. |
| 1.4.17 Solder ability | | The number of reflow times is 2 within the profile temperature. |