| Item | Requirements | Test Methods |
| Product Appearance | All components shall be properly assembled and free of burrs, warps, scratches, broken chips, and other abnormalities. Comply with method EIA 364-18B. Visual, functional, and dimensional inspection complies with applicable specification and document. | Visual Examination |
| Low Level Contact Resistance | Initial: 20m Max. Final: 70m Max. | |
| Insulation Resistance | Initial: 500 M Min. Final: 100 M Min. Comply with method EIA-364-21D. Insulation resistance is measured between adjacent contacts after applying 100V DC for 1 minute. | |
| Dielectric Withstanding Voltage | No evidence of breakdown or flash burn. No burn caused by short circuit. No insulation destruction. Current leakage: 0.50 mA Max. Comply with method EIA-364-20D, Test Method B. Apply 300V AC for 1 minute at sea level on tested plug and connectors. | |
| VSWR | Plug: 1.3 Max. (DC0.1~3GHz), 1.5 Max. (3~6GHz). Receptacle: 1.3 Max. (DC0.1~3GHz), 1.4 Max. (3~6GHz). Measure the VSWR as shown by the network analyzer. Frequency: 100M~6GHz. | |
| Un-mating force | Total un-mate force: Initial 5N Min. after 30 cycles 3N Min. Un-mate the receptacle connector (soldered to the test board) and plug at a speed of 253mm/minutes along the mating by the push-on/pull-off machine. | |
| Crimp strength | 5N MIN. Pull the cable as shown at a speed of 253mm/minutes by tensile strength machine. | |
| Durability | Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. No abnormality. Mate and un-mate the receptacle connector (soldered to the test board) and plug 30 cycles at a speed of 253mm/minutes. Comply with method EIA 364-09C. | |
| Cable retention force | Appearance: Looseness between the parts, chipping, breakage or other abnormality shall not occur. Electrical discontinuity: No electrical discontinuity greater than 1 micro-sec. shall occur. Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. Apply force on the cable as shown. During the testing, run 100mA DC to check electrical discontinuity. | |
| Vibration | Appearance: No abnormality. Electrical discontinuity: No electrical discontinuity greater than 1 micro-sec. shall occur. Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. Apply the following vibration to the mating connector. Frequency: 10Hz-100Hz-10Hz/approx 20 minutes. Half amplitude, peak value of acceleration: 1.5mm or 59m/s(6G). Directions, cycle: 3 mutually perpendicular directions, 3 cycles for each direction. During the testing, run 100mA DC. Comply with method EIA 364-28E. | |
| Physical shock | Appearance: Looseness between the parts, chipping, breakage or other abnormality shall not occur. Electrical discontinuity: No electrical discontinuity greater than 1 micro-sec. shall occur. Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. Apply the following vibration to the mating connector in accordance with MIL-STD-202, Method 213, Condition B. Peak value of acceleration: 735m/s(75G). Duration: 11msec. Wave Form: half sinusoidal. Directions, cycle: 6 mutually perpendicular, 3 cycles about each direction. During the testing, run 100mA DC to check electrical discontinuity. Comply with method EIA 364-27B. | |
| Humidity | Appearance: Looseness between the parts, chipping, breakage or other abnormality shall not occur. Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. Insulation resistance: Initial 500M Min., after testing 100M Min. D.W. Voltage: No creeping discharge, flashover, nor insulator breakdown shall occur. Apply the following environment to the mating connector in accordance with Temperature: 313+/-2K(40+/-2C), Humidity: 90~95%RH, Duration: 96 hours. Comply with method EIA 364-31C, Method II, Condition A. | |
| Thermal shock | Appearance: Looseness between the parts, chipping, breakage or other abnormality shall not occur. Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. Insulation resistance: Initial 500M Min., after testing 100M Min. D.W. Voltage: No creeping discharge, flashover, nor insulator breakdown shall occur. Apply the following environment to the mating connector. Temperature: 218K(-55C) for 30 min. <-> 358K(85C) for 30 min. Transition time: Max. 5 min. Number of cycles: 5 cycles. Comply with method EIA 364-32E. | |
| Temperature Life | Appearance: Looseness between the parts, chipping, breakage or other abnormality shall not occur. Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. Insulation resistance: Initial 500M Min., after testing 100M Min. D.W. Voltage: No creeping discharge, flashover, nor insulator breakdown shall occur. Apply the following environment to the mating connector. Temperature: 313+/-2K(40+/-2C), Relative Humidity: 80+/-5%RH, Gas: H2S 3+/-1ppm, Duration: 96 hours. | |
| H2S Gas | Appearance: No abnormality adversely affecting the performance shall occur. Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. Apply the following environment to the mating connector in accordance with MIL-STD-202, Method 101 Condition B. Temperature: 308+/-2K(35+/-2C), Humidity: 90~95%RH, Duration: 96 hours. | |
| Salt Spray | Appearance: No abnormality adversely affecting the performance shall occur. Contact resistance of inner contact: Initial 20m Max., after testing 40m Max. Contact resistance of ground contact: Initial 20m Max., after testing 40m Max. Apply the following environment to the mating connector in accordance with MIL-STD-202, Method 101, Condition B. Temperature: 308+/-2K(35+/-2C), Salt water density by weight: 5+/-1%, Duration: 48 hours. Comply with method EIA 364-26B, Method 101, Condition B. | |
| Solder ability | The number of reflow times is 2 within the profile. | |