86--13264592152

HanElectricity MMCX-KE

Manufacturer: HanElectricity
Model Number: MMCX-KE
Minimum Order Quantity: 1
Packaging Details: Through Hole
Delivery Time: 1 working day
Stock: 100
Description: 1 Inner Bore MMCX Board Side Positive Pin -40℃~+125℃ 6GHz 50Ω 3.45mm Through Hole Coaxial Connector (RF) Assemblies RoHS
Inquiry Now
Get A Quote
Specifications
Number Of Ports:
1
Interface:
Inner Bore
RF Series:
MMCX
Connector Type:
Board Side
Style:
Positive Pin
Rated Voltage:
335V
Operating Temperature:
-40℃~+125℃
Frequency:
6GHz
Impedance:
50Ω
Interface Diameter:
3.45mm
Product Description

Product Overview

The REMEHREFRRAA series from HANYONES ELECTRONICS CO., LTD. offers high-performance antennas designed for various applications. This product line includes the MMCX-KE antenna type, known for its robust electrical specifications and reliable performance.

Brand

Brand

HANYONES ELECTRONICS CO., LTD.

Model Name

MMCX-KE

Part Name

MMCX-KE X. 025

Drawing Number

13

Scale

1:1

Tolerance

X.XX 0.20, X.X 0.15

Material (Shell)

A1

Material (Contact Pin)

A4

Material (Socket)

AR

Material (Insulator)

RM

SpecificationValueUnitNotes
Antenna TypeMMCX-KE
Impedance50
VSWR<1.2+0.02f(GHz)
Frequency Range0-6GHz(4K FE45)
DC Voltage35V max
Withstand Voltage750Vrms
Contact Resistance< 5m (4K)< 2.5 m (4K F:4&)
Insulation Resistance> 1000M
Insert Loss< 0.15dB(6GHz)
RF Leakage-60 / -90dB(@ 2-3GHz)
Durability (mating)500X
Operating Temperature-40 to +125C(-40 to +85 for CABLE)

Test Equipment

Measurement TypeEquipment
VSWR and Input ImpedanceAgilent 8753/E5071 Network Analyzer
Antenna Gain and EfficiencyETS three-dimensional anechoic chamber

Test Setup Details

ParameterDescription
VSWR MeasurementAntenna arranged on customer-provided test fixture, measured via Agilent 8720/8753 Network Analyzer.
Radiation Pattern and Gain Measurement3D chamber with <-40dB reflectivity (800MHz to 6GHz), 40cm spherical quiet zone. Calibration using dipoles and standard gain horns. Antenna under test on turntable with decoupling sleeve to reduce feed line radiation. Results obtained from control system.