86--13264592152

HRS C.FL-R-SMT-1(90)

Manufacturer: HRS
Model Number: C.FL-R-SMT-1(90)
Minimum Order Quantity: 67
Packaging Details: SMD
Delivery Time: 8-15 working days
Stock: 11096
Description: Connector Receptacle 50Ω
Inquiry Now
Get A Quote
Specifications
Number Of Ports:
1
Connector Type:
Board Side
Operating Temperature:
-10℃~+40℃
Frequency:
30GHz
Impedance:
50Ω
Product Description

Product Overview

This product is designed for applications demanding high reliability, particularly in automotive equipment and devices. It offers robust electrical and mechanical characteristics suitable for demanding environments.

Brand
HIROSE ELECTRIC CO., LTD.
Model/Part Number
CL331-22000-90
Specification Sheet
C.FL-R-SMT-1(90)
Characteristic Rating Condition/Notes
Operating temperature range -20 C to +70 C 90 %RH Max.
Storage temperature range -40 C to +90 C 90 %RH Max.
Contact resistance (Center contact) 60 m Max. 10 mA Max. (DC or 1000 Hz)
Contact resistance (Outer contact) 20 m Max. 10 mA Max. (DC or 1000 Hz)
Insulation resistance 500 M Min. 100V DC
Withstanding voltage 200 V AC for 1 min. Current leakage 2 mA Max.
Voltage standing wave ratio (VSWR) 1.5 Max. 0 to 15 GHz
Voltage standing wave ratio (VSWR) 2.0 Max. 15 to 20 GHz
Voltage standing wave ratio (VSWR) 2.5 Max. 20 to 30 GHz
Contact insertion force 30 N Max. Measured with an applicable connector.
Contact extraction force 3 to 25 N Measured with an applicable connector.
Mechanical operation 20 times Insertion and extractions.
Vibration 1.5 mm (single amplitude) 10 to 100 Hz, over 5 cycles in 3 directions.
Shock 59 m/s over 5 cycles in 3 directions.
Shock (Pulse) 735 m/s directions of pulse 11 ms at 3 times in 6 directions.
Cable clamp strength (Against cable pull) --- Using a pulling tester. (Details not fully specified)
Damp heat --- Exposed at +40 C, 95 %RH, total 96 h (4 cycles).
Insulation resistance (at high humidity) 10 M Min. After Damp Heat test.
Insulation resistance (when dry) 500 M Min. After Damp Heat test and drying.
Rapid change of temperature --- Under 5 cycles. (30 min. at low temp, 3 min. at high temp)
Test Type Description Notes
General examination Visually and by measuring instrument. According to drawing.
Marking Confirmed visually.
Contact resistance Center contact 65 m Max., Outer contact 25 m Max. 1) No electrical discontinuity of 1 s. 2) No damage, cracks or looseness of parts.
Insulation resistance 10 M Min. (at high humidity) 3) No damage, cracks or looseness of parts.
Insulation resistance 500 M Min. (when dry) 3) No damage, cracks or looseness of parts.
Withstanding voltage No flashover or breakdown. 2) No damage, cracks or looseness of parts.