| Impedance | 50 Ohms |
| Frequency Range | DC to 26.5 GHz (Straight semi-rigid cable connectors and field replaceable connectors) |
| Hermetic Seal Feedthrough Notes | Mount flush as possible with housing. Slight chamfer may be used if completely filled with solder. Dimensions achieve 50 Ohms with air or Teflon insulator. |
| Hermetic Seal Feedthrough Electrical | - Impedance: 50 Ohms
- Frequency Range: DC to 26.5 GHz
- Working Voltage: 250 Vrms max at sea level
- Dielectric Withstanding Voltage: 500 Vrms min at sea level
- Insulation Resistance: 5000 Megohm min
- Insertion Loss: .015F dB max (F in GHz)
|
| Hermetic Seal Feedthrough Environmental | - Hermeticity: 1x10-8 cc/sec at one atmosphere
- Solderability: MIL-STD-202, Method 209
- Operating Temperature: -55C to 165C
|
| Hermetic Seal Feedthrough Part Numbers & Dimensions (Nominal) | | Part Number | Item 1 (Kovar) | Item 2 (Glass) | Item 3 (Kovar) | A | B | C | D | E | | 142-1000-001 | Gold pl .00005 min over Nickel pl .000005 min | Corning 7052 | Gold pl .00005 min over Nickel pl .000005 min | .070 (1.78) | .0625 (1.59) | .180 (4.57) | .0985 (2.50) | .012 (.30) | | 142-1000-002 | Gold pl .00005 min over Nickel pl .000005 min | Corning 7070 | Gold pl .00005 min over Nickel pl .000005 min | .072 (1.83) | .0625 (1.59) | .180 (4.57) | .0985 (2.50) | .015 (.38) | | 142-1000-003 | Gold pl .00005 min over Nickel pl .000005 min | Corning 7070 | Gold pl .00005 min over Nickel pl .000005 min | .072 (1.83) | .0600 (1.52) | .180 (4.57) | .1100 (2.79) | .018 (.46) | | 142-1000-004 | Gold pl .00005 min over Nickel pl .000005 min | Corning 7052 | Gold pl .00005 min over Nickel pl .000005 min | .070 (1.78) | .0600 (1.52) | .203 (5.16) | .1580 (4.01) | .020 (.51) | |
| Hermetic Seal Mounting Hole Detail (Dimensions) | | Part Number | F | G | H | H | | 142-1000-001 | .012 (0.30) | .063 (1.60) | .102 (2.59) | .028 (0.71) | .039 (0.99) | | 142-1000-002 | .015 (0.38) | .063 (1.60) | .102 (2.59) | .035 (0.89) | .049 (1.24) | | 142-1000-003 | .018 (0.46) | .060 (1.52) | .114 (2.90) | .042 (1.07) | .059 (1.50) | | 142-1000-004 | .020 (0.51) | .060 (1.52) | .162 (4.11) | .046 (1.17) | .065 (1.65) | |
| SMA - 50 Ohm Connectors Frequency Range | - Dummy loads: 0-2 GHz
- Flexible cable connectors: 0-12.4 GHz
- Uncabled receptacles, RA semi-rigid and adapters: 0-18.0 GHz
- Straight semi-rigid cable connectors and field replaceable connectors: 0-26.5 GHz
|
| SMA - 50 Ohm Connectors VSWR (f = GHz) | | Connector Type | Straight Cabled | Right Angle Cabled | | RG-178 cable | 1.20 + .025f | 1.20 + .03f | | RG-316, LMR-100 cable | 1.15 + .02f | 1.15 + .03f | | RG-58, LMR-195 cable | 1.15 + .01f | 1.15 + .02f | | RG-142 cable | 1.15 + .01f | 1.15 + .02f | | LMR-200, LMR-240 cable | 1.10 + .03f | 1.10 + .06f | | .086 semi-rigid | 1.07 + .008f | 1.18 + .015f | | .141 semi-rigid (w/contact) | 1.05 + .008f | 1.15 + .015f | | .141 semi-rigid (w/o contact) | 1.035 + .005f | N/A | | Jack-bulkhead jack adapter and plug-plug adapter | 1.05 + .01f | N/A | | Jack-jack adapter and plug-jack adapter | 1.05 + .005f | N/A | | Uncabled receptacles, dummy loads | N/A | N/A | | Field replaceable (see page 59) | N/A | N/A | |
| SMA - 50 Ohm Connectors Working Voltage (Vrms maximum) | | Connector Type | Sea Level | 70K Feet | | RG-178 | 170 | 45 | | RG-316; LMR-100, 195, 200 | 250 | 65 | | RG-58, RG-142, LMR-240, .086 semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact | 335 | 85 | | .141 semi-rigid with contact and adapters | 500 | 125 | | Dummy loads | N/A | N/A | |
| SMA - 50 Ohm Connectors Dielectric Withstanding Voltage (VRMS minimum at sea level) | | Connector Type | Voltage (VRMS min) | | RG-178 | 500 | | RG-316; LMR-100, 195, 200 | 750 | | RG-58, RG-142, LMR-240, .086 semi-rigid, field replaceable, uncabled receptacles | 1000 | | .141 semi-rigid with contact and adapters | 1500 | | .141 semi-rigid w/o contact, dummy loads | N/A | |
| SMA - 50 Ohm Connectors Corona Level (Volts minimum at 70,000 feet) | | Connector Type | Voltage (Volts min) | | RG-178 | 125 | | RG-316; LMR-100, 195, 200 | 190 | | RG-58, RG-142, LMR-240, 086 semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact | 250 | | .141 semi-rigid with contact and adapters | 375 | | Dummy loads | N/A | |
| SMA - 50 Ohm Connectors Insertion Loss (dB maximum) | - Straight flexible cable connectors and adapters: 0.06 f (GHz), tested at 6 GHz
- Right angle flexible cable connectors: 0.15 f (GHz), tested at 6 GHz
- Straight semi-rigid cable connectors with contact: 0.03 f (GHz), tested at 10 GHz
- Right angle semi-rigid cable connectors: 0.05 f (GHz), tested at 10 GHz
- Straight semi-rigid cable connectors w/o contact: 0.03 f (GHz), tested at 16 GHz
- Straight low loss flexible cable connectors: 0.06 f (GHz), tested at 1 GHz
- Right Angle low loss flexible cable connectors: 0.15 f (GHz), tested at 1 GHz
- Uncabled receptacles, field replaceable, dummy loads: N/A
|
| SMA - 50 Ohm Connectors Insulation Resistance | 5000 megohms minimum |
| SMA - 50 Ohm Connectors Contact Resistance (milliohms maximum) | | Contact Type | Initial | After Environmental | | Center contact (straight cabled connectors and uncabled receptacles) | 3.0* | 4.0* | | Center contact (right angle cabled connectors and adapters) | 4.0 | 6.0 | | Field replaceable connectors | 6.0 | 8.0 | | Outer contact (all connectors) | 2.0 | N/A | | Braid to body (gold plated connectors) | 0.5 | N/A | | Braid to body (nickel plated connectors) | 5.0 | N/A | | *N/A where the cable center conductor is used as a contact | |
| SMA - 50 Ohm Connectors RF Leakage (dB minimum, tested at 2.5 GHz) | - Flexible cable connectors, adapters and .141 semi-rigid connectors w/o contact: -60 dB
- Field replaceable w/o EMI gasket: -70 dB
- .086 semi-rigid connectors and .141 semi-rigid connectors with contact, and field replaceable with EMI Gasket: -90 dB
- Two-way adapters: -90 dB
- Uncabled receptacles, dummy loads: N/A
|
| SMA - 50 Ohm Connectors RF High Potential Withstanding Voltage (Vrms minimum, tested at 4 and 7 MHz) | | Connector Type | Voltage (Vrms min) | | RG-178 | 335 | | RG-316; LMR-100, 195, 200 | 500 | | RG-58, RG-142, LMR-240, .086 semi-rigid, .141 semi-rigid cable w/o contact, uncabled receptacles | 670 | | .141 semi-rigid with contact and adapters | 1000 | |
| SMA - 50 Ohm Connectors Power Rating (Dummy Load) | 0.5 watt @ +25C, derated to 0.25 watt @ +125C |
| SMA - 50 Ohm Connectors Temperature Range | -65C to +165C |
| SMA - 50 Ohm Connectors Thermal Shock | MIL-STD-202, Method 107, Condition B |
| SMA - 50 Ohm Connectors Corrosion | MIL-STD-202, Method 101, Condition B |
| SMA - 50 Ohm Connectors Cable Retention | | Connector Type | Axial Force* (lbs) | Torque (in-oz) | | RG-178 | 10 | N/A | | RG-316, LMR-100 | 20 | N/A | | LMR-195, 200 | 30 | N/A | | RG-58, LMR-240 | 40 | N/A | | RG-142 | 45 | N/A | | .086 semi-rigid | 30 | 16 | | .141 semi-rigid | 60 | 55 | | *Or cable breaking strength whichever is less. | |
| SMA - 50 Ohm Connectors Durability | 500 cycles minimum; 100 cycles minimum for .141 semi-rigid connectors w/o contact |
| SMA - 50 Ohm Connectors Engagement Design | MIL-C-39012, Series SMA |
| SMA - 50 Ohm Connectors Engagement/Disengagement Force | 2 inch-pounds maximum |
| SMA - 50 Ohm Connectors Mating Torque | 7 to 10 inch-pounds |
| SMA - 50 Ohm Connectors Bulkhead Mounting Nut Torque | 15 inch-pounds |
| SMA - 50 Ohm Connectors Coupling Proof Torque | 15 inch-pounds minimum |
| SMA - 50 Ohm Connectors Coupling Nut Retention | 60 pounds minimum |
| SMA - 50 Ohm Connectors Contact Retention | 6 lbs. minimum axial force (captivated contacts); 4 inch-ounce minimum torque (uncabled receptacles) |
| SMA - 50 Ohm Connectors Shock | MIL-STD-202, Method 213, Condition I |
| SMA - 50 Ohm Connectors Vibration | MIL-STD-202, Method 204, Condition D |
| SMA - 50 Ohm Connectors Moisture Resistance | MIL-STD-202, Method 106 |
| Customer Drawings | Available upon request |