| Specification | Value | Conditions |
| Current Rating (Standard Signal Contact) | 3.5A max | Per contact, all contacts loaded, 25C ambient |
| Current Rating (Standard Signal Contact) | 2.6A max | Per contact, all contacts loaded, 85C ambient |
| Current Rating (Standard Signal Contact) | 8.5A max | One contact loaded, 25C ambient |
| Current Rating (Standard Signal Contact) | 6.5A max | One contact loaded, 85C ambient |
| Current Rating (T-Contact) | 3.5A max | Per contact, all contacts loaded, 25C ambient |
| Current Rating (T-Contact) | 2.6A max | Per contact, all contacts loaded, 85C ambient |
| Current Rating (T-Contact) | 8.5A max | One contact loaded, 25C ambient |
| Current Rating (T-Contact) | 6.5A max | One contact loaded, 85C ambient |
| Current Rating (Flex Circuit Assembly) | 1.0A max | Per individual track, 25C ambient |
| Working Voltage | 300V DC or AC peak | Pre-Cabled Contacts & Cable Assemblies |
| Working Voltage | 800V DC or AC peak | (General) |
| Voltage Proof | 1,200V DC or AC peak | (at 1,013mbar, sea level) |
| Contact Resistance | 20m max | Initial |
| Contact Resistance | 25m max | After Conditioning |
| Insulation Resistance | 1,000M min | Initial |
| Insulation Resistance | 100M min | After Conditioning |
| Creepage Path (contact-to-contact) | 0.35mm min | |
| Air Gap (contact-to-contact) | 0.35mm min | |
| Environmental Classification | 55/125/56 | Days at 95% RH |
| Operating Temperature Range | -55C to +125C | |
| Low Air Pressure Severity | 300 mbar (9,144m/30,000ft) | (one contact loaded) |
| Salt Spray (SRS) | Severity 2 | BS2011 Part 2.1Kb (5% Solution, 6.5/7.2pH @ 40C, 93% RH for 66 hrs) |
| Salt Spray (J-Tek & Mix-Tek) | Condition A | EIA364 Test Procedure 26 (5% Solution, 6.5/7.2pH @ 35C, 95% RH for 96 hrs) |
| Vibration Severity (Standard Signal Contact) | 10G | 10Hz to 2,000Hz, 0.75mm, 98m/s, 6 hours |
| Vibration Severity (Standard Signal Contact) | 20G | 10Hz to 81.73Hz (1.5mm pp); 57.55Hz to 2,000Hz (196.2m/s), 2 hours |
| Shock Severity (Standard Signal Contact) | 100G | 981m/s, 18 shocks |
| Bump Severity (Standard Signal Contact) | 40G | 390m/s, 4,000+10 bumps |
| Vibration Severity (T-Contact) | 40G | 10Hz to 13.6Hz (35mm pp); 13.6Hz to 41.6Hz (1.5mm pp); 41.6Hz to 2,000Hz (392.4m/s), 6 hours |
| Shock Severity (T-Contact) | 100G | 981m/s |
| Clip Retention in Body | 18N min | |
| Contact Retention in Housing | 10N min | |
| Contact Replacement in Housing (Male Crimp) | 2 operations at 10N | (Jackscrew) |
| Durability (Standard Signal Contact) | 500 operations | |
| Durability (T-Contact) | 1,000 operations | |
| Contact Holding Force (Standard Signal Contact) | 0.2N min | |
| Insertion Force (per contact, M80 Standard Signal) | 2.0N max | Mated to standard pin, no fixings |
| Insertion Force (per contact, M83 Signal) | 1.0N max | Mated to standard pin, no fixings |
| Insertion Force (per contact, T-Contact) | 4.0N max | Mated to standard pin, no fixings |
| Withdrawal Force (per contact, M80 Standard Signal) | 0.2N min | Mated to standard pin, no fixings |
| Withdrawal Force (per contact, M83 Signal) | 0.2N min | Mated to standard pin, no fixings |
| Withdrawal Force (per contact, T-Contact) | 0.5N min | Mated to standard pin, no fixings |
| Cable Contact Replacement in Housing | Up to 2 times max | |
| Contact Wipe (T-Contact) | 2.00mm min | |