| Environmental Classification | 55/125/56 | Days at 95% RH |
| Operating Temperature Range | -55C to +125C | |
| Low Air Pressure Severity | 300 mbar (9,144m/30,000ft) | (only one contact is electrically loaded) |
| Salt Spray (SRS) | Severity 2 | 5% Solution, 6.5/7.2pH @ 40C, 93% Humidity for 66 hours |
| Salt Spray (EIA364) | Condition A | 5% Solution, 6.5/7.2pH @ 35C, 95% Humidity for 96 hours |
| Vibration Severity (Standard Signal) | 10Hz to 2,000Hz, 0.75mm, 98m/s (10G) | Duration 6 hours |
| Vibration Severity (Standard Signal) | 10Hz to 81.73Hz, 1.5mm peak-to-peak; 57.55Hz to 2,000Hz, 196.2m/s (20G) | Duration 2 hours |
| Shock Severity (Standard Signal) | 981m/s (100G) | 18 shocks total |
| Bump Severity (Standard Signal) | 390m/s (40G) | 4,000+10 bumps |
| Vibration Severity (T-Contact) | 10Hz to 13.6Hz, 35mm peak-to-peak; 13.6Hz to 41.6Hz, 1.5mm peak-to-peak; 41.6Hz to 2,000Hz, 392.4m/s (40G) | Duration 6 hours |
| Shock Severity (T-Contact) | 981m/s (100G) | |
| Clip Retention in Body | 18N min | |
| Contact Retention in Housing | 10N min | |
| Contact Replacement in Housing (Male Crimp JACKSCrew) | 2 operations at 10N | |
| Durability (Standard Signal Contact) | 500 operations | |
| Durability (T-Contact) | 1,000 operations | |
| Contact Holding Force (Standard Signal Contact) | 0.2N min | |
| Insertion Force (M80 Standard Signal Contact) | 2.0N max | Per contact, mated to standard mating pin, no fixings |
| Insertion Force (M83 Signal Contact) | 1.0N max | Per contact, mated to standard mating pin, no fixings |
| Insertion Force (T-Contact) | 4.0N max | Per contact, mated to standard mating pin, no fixings |
| Withdrawal Force (M80 Standard Signal Contact) | 0.2N min | Per contact, mated to standard mating pin, no fixings |
| Withdrawal Force (M83 Signal Contact) | 0.2N min | Per contact, mated to standard mating pin, no fixings |
| Withdrawal Force (T-Contact) | 0.5N min | Per contact, mated to standard mating pin, no fixings |
| Cable Contact Replacement in Housing | Up to 2 times max | |
| Contact Wipe (T-Contact) | 2.00mm min | |
| Current Rating (Standard Signal Contact) | 3.5A max | Per contact through all contacts, 25C ambient |
| Current Rating (Standard Signal Contact) | 2.6A max | Per contact through all contacts, 85C ambient |
| Current Rating (T-Contact) | 8.5A max | One contact per connector loaded, 25C ambient |
| Current Rating (T-Contact) | 6.5A max | One contact per connector loaded, 85C ambient |
| Current Rating (T-Contact) | 3.5A max | Per contact through all contacts, 25C ambient |
| Current Rating (T-Contact) | 2.6A max | Per contact through all contacts, 85C ambient |
| Current Rating (Flex Circuit Assembly) | 1.0A max | Per individual track, 25C ambient |
| Working Voltage (Pre-Cabled Contacts & Cable Assemblies) | 300V DC or AC peak | at 1,013mbar, sea level |
| Working Voltage (Other) | 800V DC or AC peak | at 1,013mbar, sea level |
| Voltage Proof | 1,200V DC or AC peak | at 1,013mbar, sea level |
| Contact Resistance | 20m max | Initial |
| Contact Resistance | 25m max | After Conditioning |
| Insulation Resistance | 1,000M min | Initial |
| Insulation Resistance | 100M min | After Conditioning |
| Creepage Path contact-to-contact | 0.35mm min | |
| Air Gap contact-to-contact | 0.35mm min | |